<< Click to Display Table of Contents >> Navigation: User manual NorCloud > Project > Special functions > Lden setup |
Here you can set up periods, corrections and alarms for calculating Lden values.
Click on the icon in the left menu to open the Special functions menu item, then select Lden setup:
Lden and Dose setup
The following settings are available under Lden:
Field name |
Optional / Required |
Data in field |
Information |
---|---|---|---|
Function |
Required |
|
Choose between LAeq, LAFmax and LAIeq. Remember to have the function enabled in the sound setup. Only global (1 hour) values are used. |
Yellow Zone |
Optional |
Number |
Indicator line in the graph view to show as yellow and at the given level. If zero, no line will be shown. |
Red Zone |
Optional |
Number |
Indicator line in the graph view to show as red and at the given level. If zero, no line will be shown. |
Periods |
Required |
Days and day period |
Select between Weekday, Saturday or Sunday. And select between day period Day, Evening or Night. |
From, To |
Required |
Time |
This is the time from and to for the Lden periods day, evening or night. |
Penalty [dB] |
Optional |
Number |
This is the penalty for each period used for Lden calculations and it will always apply to the results. |
C.Pure Tone [dB] |
Optional |
Number |
This is the penalty for each period from pure tone used for Lden calculations. It will only apply to the results if checked in the graph for that particular day. |
C.Impulse [dB] |
Optional |
Number |
This is the penalty for each period from impulse used for Lden calculations. It will only apply to the results if checked in the graph for that particular day. |
Use the icon to delete each Lden single line setup.
When an Lden setup is enabled you can create a data view in order to view them in the graph.
Click “Save” to store the input. “Cancel” will exit without saving.